Specifications
24
Resetable Hours -
The function shows the number of the operation hours with the lamp
on that
the ColorWash 700E AT has been powered on since the counter was last reset. In
order to reset this counter to 0, press [ENTER] twice.
Lamp Strikes - Select this submenu to read the total number of the lamp strikes.
Total Hours - The function shows the total number of the lamp strikes since the ColorWash
700E AT has been fabricated.
Resetable Hours - The function shows the number of the lamp strikes since the counter was
last reset.In order to reset this counter to 0, press [ENTER] twice.
Air Filters --- Regular cleaning of the air lters is very important for the xture´s life and performance.Bildup of
dust,dirt and fog uid residues reduces the xture´s light output and cooling ability.The two items of this menu
help you to keep cleaning peeriod of the air lters.
Set alert period - Cleaning schedule for the xture depends on the operating enviroment.
It is therefore imposible to specify accurate cleaning interval.This function allows
you to change the cleaning interval of the air lters.This "alert" value is 50 hours and it
is set as default.Inspect the xture within its 50 hours of operation to see whether cleaning
is necessary.If clening is required,clean all air lters and change the value in this menu
on acceptable level.Min. level of alert period is 10 hours, max. is 300 hours.
Elapsed Time - The option allows you to read the time which remains to cleaning air lters.
The time period is set in the menu mentioned above.
Expired time period is signalized by a negative mark at the time value and a warning icon
(triangle) on the display with the following message: "Clean Air Filters"
Clean the lters and reset this menu item (by pressing "Enter" button twice while this menu
is highlighted) to start the new time countdown.
Fixture Temperatures --- Select this submenu to read the temperatures of the xture:
Current - Select this function to read the current temperatures of the xture inside (Board
Temp.,Head Temp.Ambient Temp.)
Maximum nonresetable - The function shows the max.temperatures of the xture inside
(Board Temp.,Head Temp.Ambient Temp.) since the ColorWash 700E AT has been
fabricated.
Maximum resetable - The function shows the maximum temperatures of the xture inside
(Board Temp.,Head Temp.Ambient temp.) since the respective counter was last reset.
In order to reset desired counter to 0,press [ENTER] twice.
Measurement points:
Board Temp. - temperature on the main board in the xture base.
Head Temp. - temperature of the head inside.
Ambient Temp. -
temperature of the air which is sucked to the xture base.
This temperature can be different from the real ambient temperature due to
e.g. suction of the hot air from the xture head to the base if the xture
is hanging at the ceiling. The ambient temperature should
not exceed 40°C.
The temperatures can be displayed in °C or °F- see option "Temperature unit" in Personality"
DMX Values --- Select this function to read DMX values of each channel received by the xture.
Product IDs --- Select this function to read the MAC address and RDM UID.
Software Version --- Select this function to read the software version of the xture modules:
IC1 MB.--- Main processor on the main board in the xture base
IC2 MB .--- Tilt processor on the main board in the xture base
IC3 MB. --- Pan procesor on the main board in the xture base
IC4 MB. --- EEPROM (it is not separate processor)
IC1 L.--- Strobe processor in the left arm (arm with tilt lock) of the xture.
IC2 L.--- Effect+effect rotation+ zoom processor in the left arm (arm with tilt lock) of
the xture
IC1 R.--- Cyan+CTF processor in the right arm of the xture
IC2 R.--- Yellow+Magenta+Colour wheel processor in the right arm of the xture
IC1 DS--- Display processor 1 on the display module in the xture base
IC2 DS--- Display processor 2 on the display module in the xture base