Specifications

29
If you do not want to continue in software update, you have to switch off and on the xture to leave
this option!)
3.It is recommended that you exit all programs before running this Software Uploader.
4.Start the Software Uploader program. Select desired COM and then click Connect button.
If the conection is OK, click Start Uploading button to start uploading. It will take several minutes
to perform software update.If the option "Incremental Update"isn´t checked ,all processors will be
updated (including processors with the same software version).
If you wish to update only later versions of processors, enable the Incremental Update check box.
Avoid interrupting the process. Update status is being displayed in the list window.
When the update is nished, the line with the text “The xture is successfuly updated‘ will appear
in this window and the xture will reset with the new software.
Note: In the case of interruption of the upload process (e.g. power cut), the xture remains in the update mode
and you have to repeat the software update again.
For example: The xture was switched off before nishing software upload. After switching the xture on again,
the xture is still in the update mode and the display is dark. Restart the Software Uploader program and repeat
software update from your PC.
9. Power down mode
This mode omits xture reset after switching the xture on and lowers motor powers of the xture.”Power down
mode” is useful in special cases e.g. if the xture is in a ight case and you want to set its DMX address without
taking it out from the case.To enter “Power down mode”:
Press and hold [ENTER] and at the same time switch on the Power switch.The following message appears:
Realy Skip Initial Reset?
Escape/Enter
Press [ENTER] to activate “Power down mode” without xture reset.Now you can set features and behaviour of
the xture by using “Fixture Address”menu and “Personality” menu.It is expected,that this mode will be exited by
switching the xture off ,but if you want to go directly to “normal operation mode”,execute any xture reset.
Note:All motors (except pan and tilt motors) in “Power down mode” are deactivated and switching the lamp
on from the control panel is blocked.
10. RDM
This xture is ready for RDM operation.RDM (Remote Device Management) is a bi-directional communications
protocol for use in DMX512 control systems, it is the new open standard for DMX512 device conguration and
status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely affecting
existing non-RDM equipment. By using a special „Start Code,“ and by complying with the timing specications
for DMX512, the RDM protocol allows a console or dedicated RDM controller to send commands to and receive
messages from specic moving lights.
RDM allows explicit commands to be sent to a device and responses to be received from it.
The list of commands for ColorWash 700 AT is the following.
Parameter ID Discovery command SET command GET command
DISC_UNIQUE_BRANCH *
DISC_MUTE *
DISC_UN_MUTE *
DEVICE_INFO *
SUPPORTED_PARAMETERS *
SOFTWARE_VERSION_LABEL *
DMX_START_ADDRESS * *
IDENTIFY_DEVICE * *
DEVICE_MODEL_DESCRIPTION *
MANUFACTURER_LABEL *
DEVICE_LABEL * *
SENSOR_DEFINITION *
SENSOR_VALUE *
DISPLAY_INVERT * *