Specifications

31
Supply Frequency Error
This message will appear if the frequency of the main is not standard 50 or 60 Hz.This message can appear as
a result of the interference during the lamp starting (if the lamp or igniter is old) or as a result of the interference
by neighbouring devices. In these cases the message does not affect the xture operating!
Temper.Sensor Error
The message informs you that the communication betwen the head and the main board in the xture base was
cut off (or the head temperature sensor is defective) and the lamp was automatically switched off.
Power down mode
This message will appear if the xture is switched to the "Power down mode" (e.g. xture head is overhea-
ted).
The following error messages are separated into 2 groups:
xxxx xxxx Error 1 (e.g.Colour Wheel 1 Error 1 )
xxxx xxxx Error 2 (e.g.Colour Wheel 1 Error 2 )
There are some possible reasons of faults:
Message Characteristic fault
xxxx xxxx Error 1 Magnetic sensor is permanently On (e.g. leading wire is short-
circulated,defective stepping motor, defective control circuit on the
PCB)
xxxx xxxx Error 1/xxxx xxxx Error 2 Magnetic sensor is permanently Off(e.g.leading wire is disconnected,
defective magnetic sensor,missing magnet),defective stepping motor
Colour Wheel Error 1 (Colour Wheel Error 2 )
The messsages will appear after the reset of the colour wheel if this wheel is not located in the default positi-
on.
Effect Wheel Error 1 (Effect Wheel Error 2 )
The messages will appear after the reset of the effect wheel if this wheel is not located in the default position.
Effect Index. Error 1 (Effect Index. Error 2 )
The messages will appear after the reset of the effect wheel if the beam shaper wheel ls are not located in the
default position.
Optical Zoom Error 1 (Optical Zoom Error 2 )
The messsages will appear after the reset of the zoom module if the zoom lens is not located in the default
position.
Crop Zoom Error 1 (Crop Zoom Error 2 )
The messsages will appear after the reset of the zoom module if the additional iris not located in the default
position.
Pan Error 1 (Pan Error 2)
The messages will appear after the reset of the yoke if the yoke is not located in the default position.
Tilt Error 1 (Tilt Error 2)
The messages will appear after the reset of the head if the head is not located in the default position.
Cyan Lamella Error 1 (Cyan Lamella Error 2 )
The messsages will appear after the reset of the cyan ag if the ag is not located in the default position.
Magenta Lamella Error 1 (Magenta Lamella Error 2 )
The messsages will appear after the reset of the magenta ags if the ag is not located in the default positi-
on.
Yellow Lamella Error 1 (Yelow Lamella Error 2 )
The messsages will appear after the reset of the yellow ags if the ag is not located in the default position.
CTO Lamella Error 1 (CTO Lamella Error 2 )
The messsages will appear after the reset of the CTO ag if the ag is not located in the default position.