Specifications
13. Maintenance and cleaning
It is absolutely essential that the xture is kept clean and that dust, dirt and smoke-uid residues must not build
up on or within the xture. Otherwise, the xture‘s light-output will be signicantly reduced. Regular cleaning will
not only ensure the maximum light-output, but will also allow the xture to function reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning uid is recommended, under no circumstances
should alcohol or solvents be used!
DANGER !
Disconnect from the mains before starting any
maintenance work
The front Fresnel lens will require weekly cleaning as smoke-uid tends to building up residues, reducing the
light output very quickly. Remove dust and dirt from the fans and cooling vents using a soft brush and vacuum-
-cleaner. The interior of the xture should be cleaned at least annually using a vacuum-cleaner or an air-jet.
Dichroic colour lters, CMY ags and an internal lens should be cleaned monthly.
Maintenance and service operations are only to be carried out by authorized distributors.
Important! Check the air lters periodically and clean before they become
clogged!
Clean the air lters with a vacuum cleaner, compressed air or you can wash them and put back dry.
Replacing the air lters in the xture head.
1)Disconect the xture from power.
2)Remove both top and bottom cover of the head (by loosening the 4 quarter-turn fasteners on
each cover).
3)Remove the air lters (they are xed with Velcro fastener) from grids.
4)Clean or replace the air lters.
5)Place the lters on the grid and put head cover back.
6)Reset the elapsed time counter in menu Fixture information (Fixture Information--->Air Filters--->
Elapsed Time.
grid
air lter
Velcro fastener