Specifications

13. Maintenance and cleaning
It is absolutely essential that the xture is kept clean and that dust, dirt and smoke-uid residues must not build
up on or within the xture. Otherwise, the xture‘s light-output will be signicantly reduced. Regular cleaning will
not only ensure the maximum light-output, but will also allow the xture to function reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning uid is recommended, under no circumstances
should alcohol or solvents be used!
DANGER !
Disconnect from the mains before starting any
maintenance work
The front Fresnel lens will require weekly cleaning as smoke-uid tends to building up residues, reducing the
light output very quickly. Remove dust and dirt from the fans and cooling vents using a soft brush and vacuum-
-cleaner. The interior of the xture should be cleaned at least annually using a vacuum-cleaner or an air-jet.
Dichroic colour lters, CMY ags and an internal lens should be cleaned monthly.
Maintenance and service operations are only to be carried out by authorized distributors.
Important! Check the air lters periodically and clean before they become
clogged!
Clean the air lters with a vacuum cleaner, compressed air or you can wash them and put back dry.
Replacing the air lters in the xture head.
1)Disconect the xture from power.
2)Remove both top and bottom cover of the head (by loosening the 4 quarter-turn fasteners on
each cover).
3)Remove the air lters (they are xed with Velcro fastener) from grids.
4)Clean or replace the air lters.
5)Place the lters on the grid and put head cover back.
6)Reset the elapsed time counter in menu Fixture information (Fixture Information--->Air Filters--->
Elapsed Time.
grid
air lter
Velcro fastener