Specifications

36
Replacing the air lter in the xture base
1)Disconect the xture from power.
2)Remove side fans cover by loosening the 4 quarter-turn fasteners.
3)Remove the air lter from the cover.
4)Clean or replace the air lter.
5)Place the lter on the cover and put this cover back.
6)Reset the elapsed time counter in menu Fixture information (Fixture Information--->Air Filters--->
Elapsed Time.
Replacing the fuse
Before replacing the fuse, unplug mains lead.
Procedure:
1) Unscrew the fuseholder on the rear panel of the base with a tting screwdriver from the housing
(anticlockwise).
2) Remove the old fuse from the fuseholder.
3) Install the new fuse in the fuseholder.
4) Replace the fuseholder in the housing and x it.
Specications are subject to change without notice
air lter
cover
quarter-turn fasteners