Specifications
6
4. Installation
4.1 Connection to the mains
For protection from electric shock,the xture must be earthed!
The ColorWash 700E AT is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz
AC power source from 100-240 Volts.
For use with 100-130 V supplies,the both main 6.3 A fuses has to be exchanged for 10 A fuses which
are enclosed in the packing.
To install the 10 A fuses:
1. Disconect the xture from AC power.
2. Unscrew the "live" fuseholder on the rear panel of the base with a at-tip screwdriver from the housing
(anticlockwise).
3. Remove the 6.3 A fuse from the fuseholder.
4. Put the 10 A fuse in the fuseholder.
5. Replace the fuseholder in the housing and screw it fully clockwise.
6.Repeat steps 2-5 for "neutral" fuseholder
If you need to t the power cable with a power plug that is suitable for your local AC power outlets,
installl a 3-prong grounding-type plug on the power cable.The earth has to be connected!
If you have any doubts about proper installation, consult a qualied electrician.
The occupation of the connection cables is as follows:
Cable (EU) Cable (US) Pin International
Brown Black Live L
Light blue White Neutral N
Yellow/Green Green Earth
4.2 Fitting the lamp
DANGER ! Install the lamps with the device switched off only.
Unplug from mains before !
To insert the lamp (MSR GOLD 700 FastFit):
1. Disconnect the xture from power and allow it to cool
at least 15 minutes.
2. Make sure that xture´s head is in the position as
shown on the picture.Loosen the two quarter-turn
fasteners (1) marked “X,Y“ on the lamp cover (2) to
turn the cover down.
3. Holding the lamp by its ceramic base (3), carefully
turn the lamp to the left as shown on the picture in
order to loosen the lamp from the lamp holder (4).
Gently pull the lamp out of the lamp holder
4. Holding the new lamp by its ceramics base, gently
insert the lamp to the lamp socket and turn the base
to the right. Make sure that the lamp is installed tightly
into the lamp socket.
Do not install a lamp with a higher wattage! A
lamp like this generates temperatures the device is
not designed for. Damages caused by non-obser-
vance are not subject to warranty. Please follow the
lamp manufacturer‘s
notes! Do not touch the glass bulb bare hand during the
installation!
5. Reinsert the lamp cover (2) and tighten two quarter-turn
fasteners (1) again.
1 - Quater-turn fasteners
2 - Lamp cover
3 - Lamp base
4 - Lamp holder