Specifications

DigitalSpot 5000 DT
68
25. Effect video synchronization
The synchronization option can be set separately for each gobo layer (channels Synchronization to ID). The fixture
synchronization acts with the fixture ID which is defined as the last number of fixture´s IP address. This fixture ID is
shown on the fixture´s display. The fixtures are synchronized to the one fixture - named a master fixture.
The fixtures may be controlled by the DMX but the fixture synchronization runs over ethernet network - it means
that all fixtures that are to be synchronized have to be connected to the ethernet.
Each DMX value of the synchronizing channel responds to the fixture ID of a certain fixture.
You have to set the DMX value (ID) of the master fixture on all fixtures that are to be synchronized. If the DMX
value= fixture ID, in this case the fixture is set as a master.
Example: 4 DigitalSpots 5000 DT which are synchronized through the gobo layer 1 to the fixture 3 :
IP address
Fixture ID
Synchronization to ID (
Channel 48/75)
Fixture 1 002.168.002.010 10 DMX=20
Fixture 2 002.168.002.015 15 DMX=20
Fixture 3 002.168.002.
020
20
DMX=
20
Master fixture
Fixture 4 002.168.002.021 21 DMX=20
Note: For a synchronous video projection on the layer 1, the channels InFrame High, In Frame Low, Out Frame
High, Out frame Low, Gobo control, Playback Speed have to be set at the same values on all fixtures. The same
rule proceeds for the gobo layer 2.