Specifications

10
11
1 - Shield
2 - Signal (-)
3 - Signal (+)
4 - Not connected
5 - Not connected
1 - Shield
2 - Signal (-)
3 - Signal (+)
4 - Not connected
5 - Not connected
9. DMX-512 connection
The xture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.The sockets are wired
in parallel.
Only use a shielded twisted-pair cable designed for RS-485 and 3-pin or 5-pin XLR-plugs and connectors in
order to connect the controller with the xture or one xture with another.
DMX - output DMX-input
XLR mounting-sockets (rear view): XLR mounting-plugs (rear view):
If you are using the standard DMX controllers, you can connect the DMX output of the controller directly with
the DMX input of the rst xture in the DMX chain. If you wish to connect DMX controllers with other XLR-out-
puts, you need to use adapter cables.
Building a serial DMX chain:
1.Connect the DMX output of the rst xture in the DMX chain with the DMX input of the next xture. Always
connect one output with the input of the next xture until all xtures are connected.
2.Use menu "DMX Settings " to set the DMX start address on all xtures (see "Fixture address" menu).
3.The option “Activate DMX mode" has to be conrmed in “DMX Settings" menu on all xtures.
Example:
DMX Address=173 DMX Address=78 DMX Address=1
Caution: At the last xture, the DMX cable has to be terminated with a terminator. Solder a 120 resistor
between Signal (–) and Signal (+) into a 3-pin (or 5pin) XLR plug and plug it into the DMX output of the last
xture.