MSDS

-------------------------------------------------------------------------
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE: None Known
===========================VI. REACTIVITY DATA==========================
Stability: __X____ Stable _____ Unstable
Conditions to Avoid: Protect from freezing.
Incompatibility (Materials to Avoid): Oxidizing materials
Hazardous Decomposition Products (including combustion products):
Oxides of carbon, water and organic compounds of unknown
structure.
Hazardous Polymerization: Does not occur
Conditions to Avoid: None known.
Corrosive to Metal: No Oxidizer: No
===================VII. SPECIAL HANDLING INFORMATION===================
Ventilation and Engineering Controls: Use local exhaust. Do not use
closed air circulating system. Open windows and doors, if
necessary.
Respiratory Protection: Normally none required. Use product in a well
ventilated area. Use NIOSH approved respirator if irritation to
respiratory tract. If vapors or mists are generated, wear NIOSH/MSHA
approved organic vapor/mist respirator.
Eye Protection: Chemical goggles or face shield. Gloves: Chemical
resistant gloves.
Other clothing and Equipment: If clothing becomes contaminated, remove
and clean before re-wearing.
Work Practices, Hygienic Practices: Follow all label instructions.
Protective Measures During Maintenance of Contaminated Equipment:
Use goggles and gloves when cleaning adhesive from equipment.
Maintain proper ventilation.
-3-
MSDS --
Page 4