Product Overview
Features and Benefits
• Many flame pattern types available
• Thermocouple or thermopile options
• Spark electrode available
• Horizontal or vertical gas inlet
• Several mounting bracket types
1820 SERIES PG9 REPLACEMENT
PILOT UNI-KITS
®
The 1820 Series Uni-Kits are designed to replace those hard-to-nd
ITT-General PG9 type pilots. Most Uni-Kits come with a natural gas
orice installed and a separate LP gas orice. A special 1/4”[6.35mm]
tubing adaptor is typicallu provided with nut and ball sleeve. Uni-Kits
are available with and without a 32” thermopile. These 1820 Pilot Uni-
Kits are aerated type pilots, combining the best feature of an
incinerator type pilot and a target type pilot. These pilots have non-
linting characteristics, and no air shutters or supplementary shields
requiring assembly or adjustment.
1830 (2CH & 2C SERIES) INCINERATOR-
TARGET PILOT UNI-KITS
The 1830 Series Pilot Uni-Kits is designed to be used with all
Robertshaw
®
and competitive thermocouples. Uni-Kits include an
adaptor that converts a threaded thermocouple/thermopile model 2CH
to a snap-in thermocouple type, model 2C. Most kits come with a natu-
ral gas orice installed and a separate LP gas orice. Pilot tubing size
is typically 1/4” [6.35mm] tubing. These 1830 Pilot Uni-Kits are aerated
type pilots, combining the best feature of an incinerator type pilot and
a target type pilot. These pilots have non-linting characteristics, and no
air shutters or supplementary shields requiring assembly or adjustment
are needed.
1830-700 SERIES PILOT ELECTRODES
The 1830-700 Series Pilot Uni-Kits are designed for use with the
OEM-style Pilot Ignition systems. The electrode is permanently riveted
to the pilot frame and the spark gap is xed at 1/8” [3.18mm]. These
pilots can be used to replace existing pilot assemblies or for retrot-
ting standing pilot applications when an exact replacement is desired.
Most Uni-Kits come with a natural gas orice installed and a separate
L.P. gas orice. Pilot tubing size is typically 1/4”[6.35mm]. The 1830
Pilot Uni-Kits are aerated type pilots, combining the best feature of an
incinerator type pilot and a target type pilot. These pilots have non-lint-
ing characteristics, no air shutters or supplementary shields requiring
assembly or adjustment.
Specications
• Pilot tubing ¼” [6.35mm]
• Incinerator type pilots
• Natural gas or LP
• Various lead lengths 13” to 48” [330 mm to 1220 mm]
• Various flame hoods (1, 2 or 3) with different orientations
• Left or right hand flame orientations
PILOTS
AND
IGNITORS
S & C SERIES
1800 SERIES
2CH
1820-009
6CH24-6
1830-490
6S14-2ER
1830-717