Submittal Sheet

C20
GAS VALVES
3 POSITION OUTLET PRESSURE
REDUCER BUSHINGS
UNI-LINE FACTORY INLET STRAIGHT SIDE (FPT) REGULATOR INCLUDED (NPT)
ORDER NO. MODEL SIZE (FPT) THRU (FPT) WITH PLUGS SETTING CAPACITY
1
3/4" x 1/2" 1/2" x 3/8"
700-501 7000AMV 1/2" 1/2" 1/2'' NONE * 100,000 2
700-502 7000AMVR 1/2" 1/2" 1/2" 3.5" W.C. NAT. GAS 100,000 2
700-503 7000BMV 1/2" 3/4" 1/2" NONE * 240,000 1
700-504 7000BMVR 1/2" 3/4" 1/2" 3.5" W.C. NAT. GAS 240,000 1
700-505 7000BMV 3/4" 3/4" STRAIGHT-THRU NONE * 300,000 2
700-506 7000BMVR 3/4" 3/4" STRAIGHT-THRU 3.5" W.C. NAT. GAS 300,000 2
700-507 7000BMVR-S7C 1/2" 3/4" STRAIGHT-THRU 3.5" W.C. NAT. GAS 240,000 1
700-508 7000BMVR 1/2" 1/2" STRAIGHT-THRU 3.5" W.C. NAT. GAS 240,000 2
700-509 7000AMV 1/2" 1/2" STRAIGHT-THRU NONE * 100,000
700-510 7000BMVR 3/4" 3/4" 1/2" 3.5" W.C. NAT. GAS 300,000 2 1
700-513 * * 7010BGVMV 1/2" 1/2" STRAIGHT-THRU NONE * 240,000 2
700-514 * * 7010BGVMV 1/2" 3/4" 1/2" NONE * 240,000 1
700-515 7000BMVR-LP 3/4" 3/4" STRAIGHT-THRU 10.0" W.C. L.P. GAS 485,000 2
700-517 * * 7010BGVMV 3/4" 3/4" 1/2" NONE * 300,000 2
700-521 7000MVHC-S7C 1" 1" STRAIGHT-THRU NONE * 600,000
700-522 7000MVRHC-S7C 1" 1" STRAIGHT-THRU 3.5" W.C. NAT. GAS 720,000
700-523 7000BGVMV 3/4" 3/4" STRAIGHT-THRU NONE* 300,000 2
700-524 7000BGVMVR 3/4" 3/4" STRAIGHT-THRU 3.5" W.C. NAT. GAS 300,000 2
POOL HEATER MODELS
700-511 7000BMVR-S7C 3/4" 3/4" STRAIGHT-THRU UNI-KIT 300,000 2
700MILLIVOLT
The 700 millivolt gas valves are wall thermostat actuated combination gas
valves. These controls combine a manual gas cock, automatic pilot safe-
ty valve and a millivolt operator. The automatic pilot safety is separate from
the gas cock and provides gas shutoff in case of pilot outage. Regulated
and non-regulated models are available (see ordering chart). Standard
features include: pilot outlet, pilot gas filter and pilot adjusting key. VALVES
CAN BE MOUNTED IN ANY POSITION EXCEPT UPSIDE DOWN. Consult
ordering chart for individual control specifications.
IMPORTANT WIRING INFORMATION*
Most appliances manufactured in the USA and Canada are manufactured
to meet the standards set forth by the American National Standards
Institute (ANSI). A recent revision in the standards "mis-wiring require-
ments for gas valves" was effective January 1, 1996. The reason for this
standard was so that you as a service technician could disconnect the gas
valve wires and reconnect them without making a mistake. Therefore all
Robertshaw millivolt gas valves now meet the new standard. The 700-
500 series millivolt gas valves now have a 1/4" quick connect terminal and
a 3/16" quick connect terminal on the terminal block. There is NO
termi-
nal screw (or threads) on the side that has the 3/16" terminal. If your old
application used a terminal screw, you will need to use the 3/16" adaptor
terminal that is included with this gas valve.
NOTE: Will only work with two-lead thermopiles.
PRESSURE REGULATOR CONVERSION KITS ARE SHOWN ON PAGE C25.
*
Does not apply to 700-502, 700-504 and 700-506 which still have the coaxial
connection. (Manufactured after 9730 date code.)
Electrical rating 250 MV to 750 MV
operating range
Pressure regulator factory set @ 3.5" W.C.
(optional by model)
Pilot outlet 1-1/4" tubing
Gas cock dial marking off-pilot-on
Terminal type 1/4" spade
Ambient temperature –40° to 175°F
Maximum inlet pressure 14" W.C. (1/2 PSI)
1 1000 BTU/Cu. Ft. 0.64 sp. gr. natural gas or 2500 BTU/Cu. Ft. 1.53 sp. gr. L.P. gas @ 1" W.C. pd.
See Factory Model Identification on page C12.
3-position Outlet Note
–1/2" x 1/2" NPT Models include (2) 3/8" NPT Reducer Bushings and (2) 1/2" NPT Plugs.
–1/2" x 3/4" NPT Models include 3/4" to 1/2" NPT Reducer Bushing and (2) 1/2" NPT plugs.
Factory set @ 3.5" W.C. Includes a separate L.P. Pressure regulator set at 11.0" W.C.
Has coaxial thermopile connection.
*A separate pressure regulator may be required for the system.
Refer to field adaptable 1751 regulator kits on page C25.
* * Diaphragm valve only-no gas cock or safety magnet.
Has slow opening feature for soft ignition.
•Diaphragm valve-no safety magnet.
Excellent replacement for those hard-to-find Teledyne-Lars pool heater valves.
EXCELLENT REPLACEMENTS FOR GAS VALVES . . .
USE THE COMPETITIVE GAS VALVE CROSS-REFERENCE
SHOWN ON PAGES C90-C112.
700-502
SPECIFICATIONS
ORDERING DATA