Sell Sheet

Technical Specifications
Terminal Designations
Replacement Chart
Product Weight 10.4 oz.
Electrical Rating 24VAC(18-30VAC)
1ampmaximumloadperterminal
3amptotalmaximumload
(allterminalscombined)
Temp. Control Range 45°Fto90°F(7°Cto32°C)
Accuracy ±1°F(±0.5°C)
Power 24VACwithbatteryback-upOR
3VDCbatterypowered
System Configurations
RS2110 – Single stage electric, gas, oil or
millivolt heating or heating/cooling
systems including single stage heat pump
systems.Nottobeusedwithsplit
transformersystemsor3-wire
Hydronic(HotWater)ZoneHeat
110/220 Volts.
RS2210 – Multi-stage electric, gas or oil
heating or heating/cooling systems
including multi-stage heat pump systems.
Nottobeusedwithsplit
transformersystemsor3-wire
Hydronic(HotWater)ZoneHeat
110/220 Volts.
Terminations RS2110 – C,R,O,B,G,Y1,W1
RS2210 – C,R,O,B,G,Y1,W1,E/W1,W2,L
IndividualCartonDimensions 6.75”x4.375”x1.625”
MasterCartonQuantity 6
MasterCartonDimensions 9.25”x5.625”x7.625”
MasterCartonWeight 4.2lbs.
Shipping Specifications
RS2110
Robertshaw
®
8400,8401
Braeburn
®
1000,1010,1005NC,1000TL,
1000NC
Lux DMH110
Honeywell TH1110D,TH8775C
White-Rodgers 1F78-144,1F86-344
RS2 210
Robertshaw
®
8425
Braeburn
®
1100,1210,1200NC
Lux DMP2110
Honeywell TH1210D,T8411R,TH3210D
White-Rodgers 1F72-174
Verify specific application requirements before substitution.
ECONOMY SERIES
DIGITAL NON-PROGRAMMABLE
THERMOSTATS
191 E. North Avenue
Carol Stream Illinois 60188 USA
Customer Service Telephone 1.800.304.6563
Customer Service Facsimile 1.800.426.0804
HVACCustomerService@Invensys.com
Invensys
, Robertshaw
®
and Simply the Right Choice™ are trademarks of
Invensys plc., its subsidiaries and/or affiliated companies. All other brands
mentioned may be the trademarks of their respective owners. 5/13 – 150-2080D
For Technical Service
Telephone 1.800.445.8299
Facsimile 1.630.260.7294
TechnicalService@Invensys.com
www.RobertshawTstats.com
www.InvensysControls.com
©2013 Invensys Controls
RS2110
RS2210
C
24 VAC
Common
(Battery
Operation
Only if not
present)
O
Cool Active
Reversing
Valve
(HP only)
R
24 VAC
Supply
B
Heat Active
Reversing
Valve
(HP only)
Fan
Relay
Compressor
Contactor
First Stage
Heat
(STD only)
2110 only
GY1W1
C
24 VAC
Common
(Battery
Operation
Only if not
present)
O
Cool Active
Reversing
Valve
(HP only)
R
24 VAC
Supply
B
Heat Active
Reversing
Valve
(HP only)
Fan
Relay
Compressor
Contactor
Emergency
Heat (For HP)
First Stage Heat
(For STD)
2210 only
First Stage
Heat
(STD only)
2110 only
Second
Stage or
Auxiliary
Heat
2210 only
L
Compressor
Fault Output
(24 VAC) from
Heat Pump
2210 only
GY1
E/W1
W1 W2