Specifications

6.
ENGINE
S
6-1
CHOKE
and
SPEED ADJUSTMENT
Operate the engine at no-load. Then, turn speed control lever toward “CHOKE” position until it just con-
tacts the choke/R.P.
M.
adjusting screw on choke lever (do not move choke lever.).
To
adjust the “CHOKE” start position and
HIGH
speed operating
R.P.M.,
use a tachometer or revolution
counter. Turn the adjusting
screw
in or out against the speed control lever until
the
desired no load operating
speed
is
obtained. This same position will be the start
of
the ‘CHOKE’ operation.
6-2
TO
INSTALL REMOTE CONTROL
WIRE
1.
Use
a control wire suitable for
a
.098“
(2.5
mm) diameter wire hole
and
.236“ (6
mm) diameter casing
hole.
2.
Install control wire to engine
by
control wire bracket. Use pliers and pinch bracket around casing
to
secure in place.
3.
Insert the end
of
control wire into the speed control lever.
4.
Place speed control lever in
“LOW
SPEED”
position and tighten control wire lockscrew.
Governor
Lever
Fig.
34
-
29
-