Service manual
- 24 -
1) Check the wattage of load applied to the
generator If the generator is loaded over
the rated wattage, the engine speed can
not be increased Most induction loads such
as electric motor or electric tools or welding
machine require three to five times large
wattage of their ratings at starting This
starting wattage must not exceed the rated
output of the generator
2) Check the slow set rpm
The normal idling speed by the IDLE
CONTROL is as follows :
RGX7100/7800 (USA model)
2100 to 2500 rpm
The above speed setting is for cold
engine condition If the engine speed is
out of adjusting range, move the solenoid
backward