12. To check scale accuracy, follow the CorrectWeightVericationprocedure.
WARNING
Unplug the unit before beginning service work. Incorrect use or
connections can cause electrical shock. Only qualied personnel
should perform service work.
If scale assembly and UL circuit are not calibrated, scale can overll
the tank, causing possible explosion and/or vehicle overcharge.
UL CIRCUIT CALIBRATION
NOTE: Alwayscalibratethescalerst.Thenremovethe(4)screwsthatholddown
thekeypadonthecontrolpanelbeforeattemptingtocalibratetheULcircuit.
1. Remove all weight from the scale platform.
2. Turn on the MAIN POWER.
NOTE: Iftheunitisjustbeingturnedon,thescreenwilldefaulttodisplaythe
selectedrefrigeranttype.
3. Press SHIFT/RESET until “PROGRAM” displays.
4.
When the “PROGRAM” message displays, press SHIFT/RESET and ENTER
at the same time. The “FUNC” message displays.
5. Press 6.
NOTE: Anyweightonthescalewhen 6ispressedwillnotbeshownonthedisplay.
Theunitautomaticallyzerostheweightonthescalewhen6ispressed.Ifyoure-
movetheweight,thedisplaywillshowthechangeintotalweight,butwillnotshow
anegativesign.
6. Place a known weight of EXACTLY 75 lbs. on the scale platform. The dis-
play will show “75 lb. ± .04 lbs/.02kg.”
7. Adjust the potentiometer (P1 POT) set screw just until the “HOLD” message
displays. (The potentiometer adjusting screw is located on the circuit board.)
Maintenance Procedures
NOTE:
You must have
a known weight
of 75 lb. ± .01
(34.02 kg ±.005).