12. To check scale accuracy, follow the CorrectWeightVericationprocedure.
WARNING
Unplug the unit before beginning service work. Incorrect use or
connections can cause electrical shock. Only qualied personnel
should perform service work.
If scale assembly and UL circuit are not calibrated, scale can overll
the tank, causing possible explosion and/or vehicle overcharge.
UL CIRCUIT CALIBRATION
NOTE: Alwayscalibratethescalerst.Thenremovethe(4)screwsthatholddown
thekeypadonthecontrolpanelbeforeattemptingtocalibratetheULcircuit.
1. Remove all weight from the scale platform.
2. Turn on the MAIN POWER.
NOTE: Iftheunitisjustbeingturnedon,thescreenwilldefaulttodisplaythe
selectedrefrigeranttype.
3. Press SHIFT/RESET until “PROGRAM” displays.
4.
When the “PROGRAM” message displays, press SHIFT/RESET and ENTER
at the same time. The “FUNC” message displays.
5. Press 6.
NOTE: Anyweightonthescalewhen 6ispressedwillnotbeshownonthedisplay.
Theunitautomaticallyzerostheweightonthescalewhen6ispressed.Ifyoure-
movetheweight,thedisplaywillshowthechangeintotalweight,butwillnotshow
anegativesign.
6. Place a known weight of EXACTLY 75 lbs. on the scale platform. The dis-
play will show “75 lb. ± .04 lbs/.02kg.”
7. Adjust the potentiometer (P1 POT) set screw just until the “HOLD” message
displays. (The potentiometer adjusting screw is located on the circuit board.)
Maintenance Procedures
NOTE:
You must have
a known weight
of 75 lb. ± .01
(34.02 kg ±.005).