Models 15115 15310 15510
SAFETY PRECAUTIONS WARNING! To prevent personal injury, Wear goggles when working with refrigerants. Contact with refrigerants may cause injury. Incorrect use or connections may cause electrical shock hazards. Read and follow the instructions carefully, and take precautions to avoid electrical shock hazards. Confirm that all associated devices are grounded correctly before energizing circuits. Normal operating temperature will cause certain external portions of the pump to be hot to the touch.
VacuMaster® High Performance Vacuum Pumps Congratulations on purchasing one of Robinair’s top quality VacuMaster® vacuum pumps. Your pump has been engineered specifically for air conditioning and refrigeration service, and is built for fast, thorough evacuation. You’ll appreciate these key features . . . High Vacuum Rating The one-stage rotary vane design provides powerful, quiet, high vacuum capability and ensures moisture removal, while the high pumping capacity reduces evacuation time.
Before using your vacuum pump . . . Motor Voltage Connections: Motors are designed for operating voltages ± 10% of the normal rating (see Pump Specifications). Single voltage motors are supplied fully connected and ready to operate. 1. Confirm the voltage and frequency at the outlet match the specifications on the pump motor decal. 2. Confirm the ON-OFF switch is in the OFF position before you plug the pump into an outlet. 3. The pump is shipped without oil in the reservoir.
To shut down the pump after use . . . To help prolong pump life and promote easy starting, follow these procedures for shutdown: 1. Close the manifold valve between the pump and the system. 2. Remove the hose from the pump inlet. 3. Cap the inlet port to prevent any contamination or loose particles from entering the port. To maintain your high vacuum pump . . . Vacuum Pump Oil For maximum performance, Robinair recommends changing vacuum pump oil after each use.
Oil 5. Remove the OIL FILL cap (Model 15310 or 15510) or EXHAUST Change FITTING (Model 15115), and fill the reservoir with new vacuum pump Procedure oil until the oil appears at the bottom of the sight glass. For oil capacities, contd. refer to Pump Specifications in this manual. 6. Verify the inlet ports are capped; then turn ON the pump. Allow it to run for one minute, and check the oil level.
Grounding Consult a qualified electrician when grounding instructions are not Instructions understood, or when in doubt regarding whether the product is correctly contd. grounded. Do not modify the plug provided; if the plug does not fit the outlet, have an appropriate outlet installed by a qualified electrician. This product is for use on a nominal 120V circuit. A temporary adapter may be used to connect this plug to a 2-pole receptacle when a correctly grounded outlet is not available.
Troubleshooting Guide Your VacuMaster® pump has been designed for dependable use and long life. If something should go wrong, however, the following guide will help you get the pump back into service as quickly as possible. If disassembly of the pump is required, check your warranty. The warranty may be voided by misuse or customer tampering that results in the pump being inoperable. Failure To Start 1. Check line voltage.
VacuMaster® 1-Stage Pump Specifications 15115 Voltage 15310 15510 110V / 60 Hz 110V / 60 Hz 110V / 60 Hz 1.5 CFM 3.0 CFM 5.0 CFM 115 microns 75 microns 75 microns Stages 1 1 1 Motor 1/5 HP 1/4 HP 1/2 HP Free Air Displacement Ultimate Vacuum Intake Ports Oil Capacity Power Cord Length Dimensions Net Weight 1/4 in. flare & 1/2 in. ACME 1/4 in. flare & 1/2 in. ACME 1/4 in. flare & 1/2 in. ACME 300 ml (10 oz.) 250 ml (8.5 oz.) 300 ml (10 oz.) 6 ft. 6 ft. 6 ft.
Robinair Limited Warranty Statement Rev. November 1, 2005 This product is warranted to be free from defects in workmanship, materials, and components for a period of one year from date of purchase. All parts and labor required to repair defective products covered under the warranty will be at no charge. The following restrictions apply: 1. The limited warranty applies to the original purchaser only. 2. The warranty applies to the product in normal usage situations only, as described in the Operating Manual.
Please register your product at www.robinair.com Por favor registre su producto en www.robinair.com Veuillez enregistrer votre produit á www.robinair.com Due to ongoing product improvements, we reserve the right to change design, specifications, and materials without notice. Debido a las constantes mejoras del producto, nos reservamos el derecho de cambiar el diseño, las especificaciones y los materiales sin aviso.