Tensionning the drive chain (Fig.11)
The drive chains need no tensionning since the tension is always assured by an automatic chain span-
ner.
To change the drive chain, pull the chain spanner backwards and remove the chain from the sprockets
and remove the chains.
After the chain is replaced always assure the chain spanner is well placed onto the chain.
To change the drive chain for the rise and fall of the table, pull the chain spanner lever to the back and
remove the chain.
Attention: do not turn the sprockets on one of the 4 posts of the table whilest changing the chain; this
will lead into a disorder of the parallelism of the table!
Fig.11
Problems and troubleshooting
1. The machine does not start when the start button is activated :
- workshop main fuse is switched off: power cut, power shortage, or general overload.
- main switch off: put switch on “1”.
2. Reduction of cutting speed when working :
- belt tension not correct: tension the belt
- motor overload due to incorrect feed rate: reduce the feed rate
- blunt tools: sharpen tools
3. Vibration of the machine :
- worn or damaged belt: replace the belt
- overtensionned belt: loosen belt
4. Thermal overload does not re-arm automatically after shut-off and cooling down period:
- overload is not set on automatic reset, or the overload is faulty: set on automatic, or replace.
If you cannot solve the problem yourself or you do not nd your problem in this list, please contact