Calibration of the scale on the
cross-cut fence (Fig.18)
The scale on the fence is factory set and needs no further adjustments.
To check the settings, put the stop at a certain measure and cut off a sample.
Measure the exact length of the sample, unlock the screw which holds the fence and move the fence
until the measurement corresponds to the length of the previously cut length.
The scale on the telescopic part of the fence is factory adjusted to the scale of the xed part of the
fence.
When using the telescopic extension, the second repetition stop (3) has to be set at
1550 mm to make the different scales correspond with one another. The best way to check if all
scales correspond is to make several test cuts on the different scales.
When, after some time, the wooden protection cap at the front on the cross-cut fence is cut away, a
new one has to be made according diagram g.18.
Mitre fence (Fig.19)
The at T-nut which holds the vertical rod of the wood clamp is factory set and has to stay in its position
to make the angle scale correspond.
To set the required angle : unlock the rod of the wood clamp (1), and the auto-release handle (2). To
slide the fence (5) towards the sawblade, unlock the two handles (3). Reading the angle set is done at
the back of the aluminum bracket which holds the fence.
Always set the aluminium mitre fence prole (4) as close as possible to the saw blade.
To move this aluminium prole, loosen both locking handles on the corner bracket.
Removing the complete mitre fence is easy: loosen the vertical post of the wood-clamp and the locking
handle (2) and take the fence off of the sliding table.
The at nut should always stay in the sliding table groove.