Operation Manual
NX SERIES V0913 41
– English
Fig.37
The drive chain for the feeding system on the thicknesser can very easily be lubricated by opening the
planer in feed table. Now the drive chain can be seen right next to the planer table locking bolt. The
little cover plate X0164 can be removed by removing the table locking bolt. When however the chain
has to be replaced, then the complete saw spindle table has to be taken off to reach this chain.
Problems
Troubleshooting causes and solutions Oorzaken en oplossingen
1 The machine does not start when the start switch is activated:
– main switch off;
– power supply failure;
– emergency stop button activated;
– main fuse blown;
– overload activated due to motor overload;
– fault in the electrical system or machine connection;
– planer tables opened and dust chute thicknesser not in position.
2 Reduction of speed when working:
– belt tension not correct;
– motor overload due to incorrect feed speed;
– blunt tools.
3 Vibration of the tools mounted on the spindles:
– the tool is unbalanced; replace or have the balancing done by specialised personal and equipment.
4 Thermal overload does not re-arm automatically after shut-off and cooling down period:
– overload is not set for automatic reset or have the overload is faulty
Adjusting the spindle motor brake
When after extended use of the spindle, the brake down time of the motor exceeds10 seconds the
brake will need to be re-adjusted.
Without removing the motor cowling, put a 5 mm Allen key into the countersunk bolt and turn the bolt
until the air gap between brake and ventilator fan is 0,2 mm.
Make a test run with the motor and check if the brake time is about 8 to 10 seconds.
belt spanner handle
7500
6000
4000
2900
2900 T/Min.
Speed indicator
Put the fork according
the chosen speed