Operation Manual
42 V0913 NX SERIES
– English
Option digital
read-out on the parallel fence
CHANGING THE BATTERY ON THE Z16 ELGO:
– Remove the digital reader from the cross-cut fence when changing the battery.
– This is very important: the reader may not be in contact with the magnetic tape!
– Now push F and keep on pushing it when removing the old battery.
– Place the new battery, still pushing F.
– Keep on pushing F until NO CODE appears on the screen.
– The reader is now calibrated and set at the factory settings.
– Repeat the above procedure in case of doubt about the operation of the reader.
– Calibrating the Z16 Elgo
– Calibrating the system: place the parallel fence up against the saw blade so that the teeth just touch
the fence. Now push simultaneously both buttons F and Set in order to set the read-out at 0.
– It is recommended that each time a new saw blade is put on to the machine the system is
calibrated again.