Option A5216: Retro-t digital read-out
for parallel fence
Adjusting the sensor is easy and simple: ip the parallel fence block over and loosen the bolts for the
different brackets.
After adjustment is done, make sure all bolts are well tightened.
The calibration of the read-out is easy and simple: slide the alu saw fence up against the saw blade so
that the teeth just touch the fence, and now push simultaneous both buttons F and SET, now the read-
out is set at 0.
Now slide the fence a couple of mm’s to the right, thus preventing the fence making contact with
the saw blade, and slide the stop ring up against the parallel fence support and lock the bolt. It is
recommended that each time a new saw blade is put onto the machine to calibrate again.