Explanation of accoustic levels
The values given are the emission levels; these are not necessarily the levels at which the operator
can work safely.
Although there is a link between the emission values and the exposition level, it cannot be used in a
reliable way to determine if supplementary measures should be taken.
NOISE INFORMATION
- measurements : as per ISO norm 7960
- as per annexe D
Workpost under load
Level continuous
accoustic pressure as
per index A
dB (A)
Level accoustic
power
dB (A) (MW)
Max. value accoust.
pressure as per index
C (instantaneous)
dB
Saw 91 105 (26,3) < 130
The dust emission examination was carried out by the following approved body :
Prünstitut für Holzstaubmessungen
Institut für Werkzeugmaschinen
Universität Stuttgart - Germany
Measurements as per DIN 33 893 (GS-HO-05)
Measurement values show that the TRK-value of 2 mg/m3 has not been exceeded.
Notication number and date : 08.03.1996/FPH-AZ : 029/95