Starting up the machine SD410
(Fig 2)
Turn the main switch Q1 (1) to position “ 1” in order to put the machine under tension.
The motor for the planer arbor can be started by pressing the start button. (1) The engine starts
automatically in “star - triangle.
By pressing the start button (2) the feeding motor starts.
In the comfort pack, the feeding speeds can be selected with the switch (3) there is a choise between
two speeds, pos = 1 6m/min - pos 2 = 12m/min.
To stop the feeding motor, press the stop button (5).
All engines are switched off when the stop button or emergency button (6) are pressed.
There is an emergency stop button on the infeed side of the machine.
It is not possible to start the machine with opened planer table and the guard in planing position the
machine. The guard must be put in thicknessing position before the machine can be started.
23
4 5
6
1
Fig.2
Aspiration (Fig 3)
For your health and that of your employees, it is recommended to connect to an exhaust system to the
machine.
The machine is equipped with a suction port of 120 mm diameter.
The ow rate must be at least 20 m/sec measured at the machine. The total air ow must be at least
1500 m³/h.