Operation Manual

EN
18
Add pegs in to pull
the perimeter wire down
to the ground surface,
below the grass tips.
Add pegs in to pull
the perimeter wire down
to the ground surface,
below the grass tips.
Important
If the lawn's edge borders with a pond, swimming pool or watercourse or where the grass level is
higher than 70cm (2ft) from the edge around it, then it is required to keep a distance of at least 1.2m
(4ft) between the wire and the water (or chasm) otherwise supplement a fence or the same along the
lawn's edge, so Robomow can detect it. The height must then be at least 15cm (6 inch). This will
prevent Robomow, under any circumstances, from crossing the wire outside the working area
1.4.3 Fastening the Wire to the Ground
It is not necessary to bury the perimeter wire, though you may do so if you wish, up to 10 cm
(4 inches) deep.
Small pegs or stakes are supplied with the Robomow and they are used to fasten and hold the
perimeter wire to the ground, below grass level.
Initially place a minimum number of pegs to fasten the wire down. Remember that you will want to
test the wire set up before you fill in additional pegs and you may find some areas where you will
need to move the wire position slightly.
Upon hammering the peg to its final depth in the ground, pull the wire tight. It is a lot easier to insert
pegs into wet soil. If the soil is dry, water the yard before perimeter wire set up.
Pegs should be driven at distances between one
another that will keep the wire down below the
grass level and prevent it from becoming a tripping
hazard (Figure 1.14).
When properly fastened to the ground, the wire and
pegs will soon disappear under the growth of new
grass and will not be visible.
If additional wire is required in order to complete
the set-up, use the wire connectors provided, which
are water-proof, to connect between the two wire
ends, as explained in chapter 5.6.
WARNING!
Damage to the eye is possible. Use proper eye protection and wear
appropriate work gloves when hammering the pegs. Hard or dry ground
may cause pegs to break when driving them in. In extreme cases,
watering the lawn where the pegs will be driven can be beneficial.
IMPORTANT INFORMATION!
Screw terminals or twisted cables, insulated with insulation tape is not a satisfactory splice. Soil
moisture will cause the stripped wire ends to oxidize and after a while result in broken circuit.
Figure 1.14 -
Pegging the Perimeter Wire
Short distance of
RoboRuler - where the
area outside the
immediate perimeter is
free of obstacles and is the
same relative height as the
perimeter edge or lower
Long distance of
RoboRuler – where the
area outside the
immediate perimeter has
obstacles or differences in
the height along the
perimeter edge
Figure 1.13 –
Using the RoboRuler