User Manual

Table Of Contents
Commands Reference
200 Advanced Digital Motor Controller User Manual V2.0, July 8, 2019
Syntax Serial: !SPL ee nn
Syntax Scripting: SetCommand(_SPL, ee, nn)
Arguments: 2
Argument 1: Eelment Type: Unsigned 8-bit
Min: 1 Max: 2 × Total number of motors
Argument 2: Value Type: Unsigned 32-bit
Where:
ee =
1: Min amount for channel 1
2: Max amount for channel 1
3: Min amount for channel 2
4: Max amount for channel 2
2 × (m - 1) + 1: Min amount for channel m.
2 × (m - 1) + 1: Max amount for channel m.
nn = Velocity max/min amount
TC – Target Torque (DS402)
Alias: TC HexCode: 5B CANOpen id: 0x6071
Description:
This command configures the input value in 100×Nm for the torque where the controller
in torque mode.
Syntax Serial: !TC cc nn
Syntax Scripting: SetCommand(_TC, cc, nn)
Arguments: 2
Argument 1: Channel Type: Unsigned 8-bit
Min: 1 Max: Total number of motors
Argument 2: Value Type: Signed 16-bit
Where:
cc = Motor channel
nn = Torque input value in 100×Nm