User Manual

Table Of Contents
DS402 Runtime Queries
Advanced Digital Motor Controller User Manual 243
Syntax Serial: ?VAR [ee]
Argument: VarNumber
Min: 1 Max: Total Number of User Variables
Syntax Scripting: result = getvalue(_VAR, ee)
Reply:
VAR=nn Type: Signed 32-bit Min: -2147M Max: 2147M
Where:
ee = Variable number
nn = Value
SL - Read Slip Frequency
Alias: SL HexCode: 48 CANOpen id: 0x2136
Description:
This query is only used in AC Induction boards. Read the value of the Slip Frequency be-
tween the rotor and the stator of an AC Induction motor.
Syntax Serial: ?SL [cc]
Argument: VarNumber
Min: 1 Max: Total Number of Motors
Syntax Scripting: result = getvalue(_SL, cc)
Reply:
SL=nn Type: Signed 16-bit Min: -32768 Max: 32768
Where:
cc = Motor channel
nn = Slip Frequency in Hertz * 10
DS402 Runtime Queries
Runtime queries created to support DS402 specification are described below:
TABLE 15-11.
Command Arguments Description
AOM Channel Modes of Operation Display (DS402)
CW Channel Control Word (DS402)
F Channel Velocity/Position Actual Value (DS402)