User Manual

Table Of Contents
DS402 Runtime Queries
Advanced Digital Motor Controller User Manual 253
Reply: SW=nn
Syntax Scripting: nn = GetValue(_SW, cc)
Argument: Channel Type: Unsigned 8-bit
Min: 1 Max: Total number of motors
Result: Value Type: Unsigned 16-bit
Where:
cc = Motor channel
nn = Status word value
TC – Target Torque (DS402)
Alias: TC HexCode: 5B CANOpen id: 0x6071
Description:
Read the configured target torque in 100×Nm when the controller in torque mode.
Syntax Serial: ?TC [cc]
Reply: TC=nn
Syntax Scripting: nn = GetValue(_TC, cc)
Argument: Channel Type: Unsigned 8-bit
Min: 1 Max: Total number of motors
Result: Value Type: Signed 16-bit
Where:
cc = Motor channel
nn = Torque input value in 100×Nm
TRQ – Target Torque (DS402)
Alias: TRQ HexCode: 7A CANOpen id: 0x6077
Description:
Read the actual torque in 100×Nm.
Syntax Serial: ?TRQ [cc]