Maintenance Commands
Advanced Digital Motor Controller User Manual 259
CLMOD – Motor/Sensor Setup
Argument: None
Description:
This command is used in order to perform motor and/or sensor setup, in cases of DC
brushless motor controllers, when working in Sinusoidal mode or in Sensorless mode.
This command will make the motor spin either slowly (sinusoidal) or even fast (sensor-
less) and will configure accordingly the respective fields in order to have a smooth motor
spin and alignment between the motor and the sensor directions. During setup no motor
command can be applied to the motors. For more details see Section 8.
Note: The motor will spin.
Syntax: %CLMOD nn
Where:
0: Exit/Stop Setup Mode.
2: Setup channel 1.
3: Setup channel 2.
CLRST - Reset configuration to factory defaults
Argument: Key
Description:
This command resets all configurations to their factory default
Syntax:
%CLRST safetykey
Where:
safetykey = 321654987
CLSAV - Save calibrations to Flash
Argument: Key
Description:
Saves changes to calibration to Flash. Calibration parameters are stored permanently until
new values are stored.. This command must be used with care and must be followed by
a 9-digit safety key to prevent accidental use.
Syntax:
%CLSAV safetykey
Where:
safetykey = 321654987