User Manual

Table Of Contents
General Configuration and Safety
Advanced Digital Motor Controller User Manual 277
Syntax Scripting: setconfig(_SKLIN, cc)
Number of Arguments:
Argument 1: Channel
Min: 1 Max: 2
Argument 2: Linearity
Type: Unsigned 8-bit
Min: 0 Max: 6
Default: 0 = Linear
Where:
cc = Input channel number
nn =
0 : linear (no change)
1: exp weak
2: exp medium
3: exp strong
4: log weak
5: log medium
6: log strong
SKMAX - Spektrum Max
HexCode: 52
Description:
Value captured from Spektrum radio that will be considered as +1000 command
Syntax Serial: ^SKMAX cc nn
~SKMAX [cc]
Syntax Scripting: setconfig(_SKMAX, cc)
Number of Arguments:
Argument 1: Channel
Min: 1 Max: 2
Argument 2: Max
Type: Unsigned 16-bit
Min: 0 Max: 1024
Default: 0
Where:
cc = Channel
nn = Max value