User Manual

Table Of Contents
Motor Configurations
Advanced Digital Motor Controller User Manual 325
Syntax Serial: ^SMOD cc (aa + mm)
^SMOD [cc]
Syntax Scripting: setconfig(_SMOD, cc, aa)
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of SSI Sensors
Argument 2: Use
Type: Unsigned 8-bit
Min: 0 Max: 255
Default: 0 = Unused
Where:
cc = SSI Sensor channel
aa =
0: Unused
1: Command
2: Feedback
3: Absolute Feedback
mm = mot1*16 + mot2*32 + mot3*48
Example:
^SMOD 1 19 = Encoder used as absolute feedback for channel 1
THLD - Short Circuit Detection Threshold
HexCode: 04
Description:
This configuration parameter sets the threshold level for the short circuit detection. There
are 4 sensitivity levels from 0 to 3.
Syntax Serial: ^THLD nn
~THLD
Syntax Scripting: setconfig(_THLD, nn)
Number of Arguments: 1
Argument 1: Threshold
Type: Unsigned 8-bit
Min: 0 Max: 3
Default: 1 = Medium Sensitivity
Where:
nn =
0: Very high sensitivity
1: Medium sensitivity
2: Low sensitivity
3: Short circuit protection disabled