User Manual

Table Of Contents
Commands Reference
346 Advanced Digital Motor Controller User Manual V2.0, July 8, 2019
Syntax Serial: ^ILLR cc nn
~ ILLR [cc]
Syntax Scripting: setconfig(_ILLR, cc, nn)
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Rotor Leakage Inductance
Type: Unsigned 32-bit
Min: 0 Max: 10000
Default: 10
Where:
cc = Motor channel
nn = Motor’s Rotor Leakage Inductance in μH.
Example:
^RFC 1 67: Set Rotor Leakage Inductance of motor 1 to value 67μH.
IRR - Rotor Resistance
HexCode: 99
Description:
This parameter is only used for AC Induction controller when operating in FOC mode and
contains the resistance per phase of the rotor. This value can be obtained from the motor
supplier.
Syntax Serial: ^IRR cc nn
~ IRR [cc]
Syntax Scripting: setconfig(_IRR, cc, nn)
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Rotor Resistance