User Manual

Table Of Contents
CAN Communication Commands
Advanced Digital Motor Controller User Manual 349
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Rotor Flux Current
Type: Unsigned 16-bit
Min: 0 Max: 500
Default: 10
Where:
cc = Motor channel
nn = Motor’s Rotor Flux Current in Amps * 10
Example:
^RFC 1 50: Set Rotor Flux Current for motor 1 to value 5A.
CAN Communication Commands
This section describes all the configuration parameters uses for CANbus operation.
TABLE 15-25. CANbus Commands
Command Arguments Description
CAS Rate CANOpen Auto start
CBR BitRate CAN Bit Rate
CEN Mode CAN Enable
CHB HeartBeat CAN Heartbeat
CLSN Address CAN Listening Node
CNOD Address CAN Node Address
CSRT Rate MiniCAN SendRate
CTPS TPDOnbr Rate CANOpen TPDO SendRate
CTT None CANOpen Transmission Type
FSA None DS402 FSA
CAS - CANOpen Auto start
HexCode: 5A
Description:
Determines if device is an active CANOpen node at power up. When set, node is in oper-
ational state at power up without the need to receive a start command.
Syntax Serial: ^CAS nn
~CAS