User Manual

Table Of Contents
Commands Reference
356 Advanced Digital Motor Controller User Manual V2.0, July 8, 2019
Where:
cc = octet
nn = octet value
Example:
^GWA 1 192_^GWA 2 168_^GWA 3 2_^GWA 4 1: Set Gateway Address 192.168.2.1.
IPA - IP Address
HexCode: 68
Description:
Configure this parameter in order to set the IP Address. IP Address option includes 4 val-
ues representing each octet in the IP address v4 format. The default IP address, if DHCP
is disabled, is 192.168.1.20.
Syntax Serial: ^IPA cc nn
~IPA
Syntax Scripting: setconfig(_IPA, cc, nn)
Number of Arguments: 2
Argument 1: IP Octet
Type: Unsigned 8-bit
Min: 1 Max: 4
Argument 2: IP Address
Type: Unsigned 8-bit
Min: 0 Max: 255
Default:
Octet Value
1 192
2 168
3 1
4 20
Where:
cc = octet
nn = octet value
Example: