User Manual

Table Of Contents
TCP Communication Commands
Advanced Digital Motor Controller User Manual 357
IPP - IP Port
HexCode: 6B
Description:
Configure this parameter in order to set the IP Port. Default IP Port value is 9761. The IP
address combined with the IP Port value are used to connect to the controller.
Syntax Serial: ^IPP nn
~IPP
Syntax Scripting: setconfig(_IPP, nn)
Number of Arguments: 1
Argument 1: IP Port
Type: Unsigned 16-bit
Min: 0 Max: 65535
Default: 9761
Where:
nn = IP Port
Example:
^IPP 1300: Set IP Port 1300.
PDNS - Primary DNS
HexCode: 6D
Description:
Configure this parameter in order to set the address of the primary DNS server. Primary
DNS option includes 4 values representing each octet in the IP address v4 format. Prima-
ry DNS server default address is 192.168.1.1.
Syntax Serial: ^PDNS cc nn
~PDNS
Syntax Scripting: setconfig(_PDNS, cc, nn)
Number of Arguments: 2
Argument 1: IP Octet
Type: Unsigned 8-bit
Min: 1 Max: 4
Argument 2: Primary DNS
Type: Unsigned 8-bit
Min: 0 Max: 255
Default: