Enabling MultiPWM Communication
Advanced Digital Motor Controller User Manual 73
Any of the controller’s pulse input can be configured as a MultiPWM input. The diagram
below shows how simple this one-wire interfacing is.
Motor Controller
Sensor
MultiPWM
Pulse Input
GND
5V Out or
7-30V Supply
FIGURE 5-1: One-wire interfacing using MultiPWM
Enabling MultiPWM Communication
Magnetic Sensor and Flow Sensor are set to MultiPWM mode in its factory default con-
figuration, while the Battery Management System needs to be explicitly configured. To
enable the capture, the selected pulse input on the controller must be configured to the
respective option when using the PC utility.
When changing via the console use
^PMOD cc nn to enable pulse input cc in MultiPWM mode.
Where nn:
4: For Magnetic Sensor
5:For Battery Management System
7: For Flow Sensor