User Manual

Table Of Contents
Motor Operating Features and Options
88 Advanced Digital Motor Controller User Manual V2.0, July 8, 2019
The controller supports 3 mixing algorithms with different driving characteristics.
The table below shows how each motor output responds to the two commands
in each of these modes.
TABLE 7-1. Mixing Mode characteristics
Input Mode 1 Mode 2 Mode 3
Throttle Steering M1 M2 M1 M2 M1 M2
0 0 0 0 0 0 0 0
0 300 300 -300 300 -300 300 -300
0 600 600 -600 600 -600 600 -600
0 1000 1000 -1000 1000 -1000 1000 -1000
0 -300 -300 300 -300 300 -300 300
0 -600 -600 600 -300 300 -600 600
0 -1000 -1000 1000 -1000 1000 -1000 1000
300 300 600 0 600 0 522 90
300 600 900 -300 900 -300 762 -120
300 1000 1000 -700 1000 -1000 1000 -400
300 -300 0 600 0 600 90 522
300 -600 -300 900 -300 900 -120 762
300 -1000 -700 1000 -1000 1000 -400 1000
600 300 900 300 900 300 708 480
600 600 1000 0 1000 -200 888 360
600 1000 1000 -400 1000 -1000 1000 200
600 -300 300 900 300 900 480 708
600 -600 0 1000 -200 1000 360 888
600 -1000 -400 1000 -1000 1000 200 1000
1000 300 1000 700 1000 400 900 1000
1000 600 1000 400 1000 -200 1000 1000
1000 1000 1000 0 1000 -1000 1000 1000
1000 -300 700 1000 400 1000 1000 900
1000 -600 400 1000 -200 1000 1000 1000
1000 -1000 0 1000 -1000 1000 1000 1000
Motor Channel Parameters
User Selected Current Limit Settings
The controller has current sensors at each of its output stages. Every 1 ms, this current
is measured and a correction to the output power level is applied if higher than the user
preset value.
The current limit may be set using the supplied PC utility. The maximum limit is dependent
on the controller model and can be found on the product datasheet.