Commands Types
Advanced Digital Motor Controller User Manual 217
SECTION 19
Commands
Reference
This section lists all the commands accepted by the controller. Commands are typically
sent via the serial (RS232 or USB) ports (See “Serial (RS232/USB) Operation” on page
141). Except for a few maintenance commands, they can also be issued from within a user
script written using the MicroBasic language (See “MicroBasic Scripting” on page 179).
Commands Types
The controller will accept and recognize four types of commands:
Runtime commands
These start with “!” when called via the serial communication (RS232 or USB), or using
the setcommand() MicroBasic function. These are usually motor or operation commands
that will have immediate effect (e.g. to turn on the motor, set a speed or activate digital
output). Most of Runtime commands are mapped inside a CANopen Object Directory,
allowing the controller to be remotely operated on a CANopen standard network (See
“CANopen Interface” on page 172). See “Runtime Commands” on page 164 for the full
list and description of these commands.
Runtime queries
These start with ?” when called via the serial communication (RS232 or USB), or using
the getvalue() Microbasic function. These are used to read operating values at runtime
(e.g. read Amps, Volts, power level, counter values). All runtime queries are mapped in-
side a CANopen Object Directory, allowing the controller to be remotely interrogated on a
CANopen standard network (See “CANopen Interface” on page 172). See Runtime com-
mands are commands that can be sent at any time during controller operation and are tak-
en into consideration immediately. Runtime commands start with “!” and are followed by
one to three letters. Runtime commands are also used to refresh the watchdog timer to
ensure safe communication. Runtime commands can be called from a MicroBasic script
using the setcommand() function..
Maintenance commands
These are only available trough serial (RS232 or USB) and start with “%”. They are used
for all of the maintenance commands such as (e.g. set the time, save configuration to EE-
PROM, reset, load default, etc.).