User Manual

Table Of Contents
Sinusoidal Commutation
Advanced Digital Motor Controller User Manual 117
FIGURE 8-23. Diagnostic Tab with Auto Setup
Select which motor channel to setup. Then click on the Motor/Sensor Setup button to
launch the Automatic process. The process can also be initiated using the serial com-
mands %CLMOD 2 for Channel 1 and %CLMOD 3 for Channel 2.
The motor will rotate at a RPM speed of 60/Number of Pole pairs. It will perform a full
turn in each direction and then stop. If the motor doesnt turn, or turns with hesitations,
Click on the Cancel button (or send %CLMOD 0). Make sure that the motor is not loaded.
Adjust the Reference Search Current and try again. See “Reference Search Power” on
page 108.
After setup is finished, depending on the sensor type, the Utility will print the following
captured parameters on the console tab indicating that the process is complete:
TABLE 8-2. Motor/Sensor Setup parameters
Sensor Captured Values Description
All types BADJ
SWD
Zero Reference
Winding/Sensor Order
Hall, Hall+Encoder HSAT Hall Sensor Map
Sin/Cos, Resolver ZSMC Min/Max/Zero