User Manual

Table Of Contents
Commands Reference
194 Advanced Digital Motor Controller User Manual V2.1, December 3, 2020
CSS - Set SSI Sensor Counter
Alias: - HexCode: 6C CANOpen id: 0x201F
Description:
This command loads the SSI Sensor counter with the value contained in the command
argument. Beware that changing the controller value while operating in closed-loop mode
can have adverse effects. This command is not applicable if the respective sensor’s use
has been set as absolute feedback.
Syntax Serial: !CSS [cc] nn
Syntax Scripting: setcommand(_CSS, cc, nn)
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of SSI sensors
Argument 2: Value Type: Signed 32-bit
Min: -2147M Max: +2147M
Where:
cc = SSI sensor channel
nn = Counter value
Example:
!CSS 1 -1000 : Loads -1000 in SSI sensor counter 1
!CSS 2 0 : Clears SSI sensor counter 2
CU - Raw Redirect Send
Alias: - HexCode: 94 CANOpen id: -
Description:
This command is used to build and send Raw frames in serial interfaces (See Raw Re-
direct section in manual). It can be used to enter the outport (RS232 or RS485), frame
length, and data, one element at a time. The frame is sent immediately after the frame
length is entered, and so it should be entered last.
Syntax Serial: !CS ee nn
Syntax Scripting: setcommand(_CS, ee, nn)
Number of Arguments: 2
Argument 1: Element
Min: 1 Max: 18