User Manual

Table Of Contents
Commands Reference
202 Advanced Digital Motor Controller User Manual V2.1, December 3, 2020
Number of Arguments: 1
Argument 1: Channel Type: Unsigned 8-bit
Min: 1 Max: Total Number of Encoders
Where:
cc = Motor channel
Example:
!H 1: Loads encoder counter 1, SSI sensor counter 1 and brushless counter 1 with their
preset home values.
MG - Emergency Stop Release
Alias: MGO HexCode: 0F CANOpen id: 0x200D
Description:
The MG command will release the emergency stop condition and allow the controller to
return to normal operation. Always make sure that the fault condition has been cleared
before sending this command
Syntax Serial: !MG
Syntax Scripting: setcommand(_MG, 1)
setcommand(_MGO, 1)
Number of Arguments: 0
MS - Stop in all modes
Alias: MSTOP HexCode: 10 CANOpen id: 0x200E
Description:
The MS command will stop the motor for the specified motor channel.
Syntax Serial: !MS [cc]
Syntax Scripting: setcommand(_MS, cc)
setcommand(_MSTOP, cc)
Number of Arguments: 1
Argument 1: Channel Type: Unsigned 8-bit
Min: 1 Max: Total Number of Motors
Where:
cc = Motor channel