User Manual

Table Of Contents
Commands Reference
212 Advanced Digital Motor Controller User Manual V2.1, December 3, 2020
TABLE 15-11. Definition of bit 8
Bit Value Definition
8 0 The motion shall be executed or continued
1 Axis shall be stopped according to the halt option code (605Dh)
Note: At cyclic synchronous modes Halt function is not active
Syntax Serial: !CW cc nn
Syntax Scripting: SetCommand(_CW, cc, nn)
Arguments: 2
Argument 1: Channel
Type: Unsigned 8-bit
Min: 1 Max: Total number of motors
Argument 2: Value
Type: Unsigned 16-bit
Where:
cc = Motor channel
nn = Control word value
FEW - Following Error Window (DS402)
Alias: FEW HexCode:99 CanOpen id: 0x6065
Description:
This command indicates the configured range of the tolerated position values symmet-
rically to the position demand value. If the position actual value is out of the following
error window, a following error occurs. If the value of the following error window is FFFF
FFFFh, the following control is disabled.
Syntax Serial: !FEW cc nn
Syntax Scripting: SetCommand(_FEW, cc, nn)
Arguments: 2
Argument 1: Channel Type: Unsigned 8-bit
Min: 1 Max: Total of motors
Argument 2: Value Type: Unsigned 32-bit
Where:
cc = Motor channel
nn = Following Error Window (counts)