User Manual

Table Of Contents
Runtime Commands
Advanced Digital Motor Controller User Manual 219
3: Delta speed in 10×RPM for channel 2
4: Delta time in seconds for channel 2
2 × (m - 1) + 1: Delta speed in 10×RPM for channel m.
2 × (m - 1) + 1: Delta time in seconds for channel m.
nn = Delta speed/time
SDC – Velocity Deceleration (DS402)
Alias: SDC HexCode: 59 CANOpen id: 0x6049
Description:
This command configures the velocity deceleration.
Syntax Serial: !SDC ee nn
Syntax Scripting: SetCommand(_SDC, ee, nn)
Arguments: 2
Argument 1: Element Type: Unsigned 8-bit
Min: 1 Max: 2 × Total number of motors
Argument 2: Value Type: Unsigned 32-bit
Where:
ee =
1: Delta speed in 10×RPM for channel 1
2: Delta time in seconds for channel 1
3: Delta speed in 10×RPM for channel 2
4: Delta time in seconds for channel 2
2 × (m - 1) + 1: Delta speed in 10×RPM for channel m.
2 × (m - 1) + 1: Delta time in seconds for channel m.
nn = Delta speed/time
SPC - Target Profile Velocity (DS402)
Alias: SPC HexCode: 66 CanOpen id: 0x60FF
Description:
Sets the required velocity of the system in RPM. Positive values shall indicate forward di-
rection and negative values shall indicate reverse direction. This command is applicable to
profile velocity and cyclic synchronous velocity modes.