f4 = Bottom MOSFET of V1 phase is damaged
f5 = Top MOSFET of W1 phase is damaged
f6 = Bottom MOSFET of W1 phase is damaged
f7 = Top MOSFET of U2 phase is damaged
f8 = Bottom MOSFET of U2 phase is damaged
f9 = Top MOSFET of V2 phase is damaged
f10 = Bottom MOSFET of V2 phase is damaged
f11 = Top MOSFET of W2 phase is damaged
f12 = Bottom MOSFET of W2 phase is damaged
T - Read Temperature
Alias: TEMP HexCode: 12 CANOpen id: 0x210F
Description:
Reports the temperature at each of the Heatsink sides and on the internal MCU silicon
chip. The reported value is in degrees C with a one degree resolution.
Syntax Serial: ?T [cc]
Argument: SensorNbr
Min: 1 Max: Total Number of Motors + 1
Syntax Scripting: result = getvalue(_T, cc)
result = getvalue(_TEMP, cc)
Reply:
T= cc Type: Signed 8-bit Min: -40 Max: 125
Where:
cc =
1 : MCU temperature
2 : Channel 1 side
3 : Channel 2 side
tt = temperature in degrees
Note:
On some controller models, additional temperature values may reported. These are mea-
sured at different points and not documented. You may safely ignore this extra data. Other
controller models only have one heatsink temperature sensor and therefore only report
one value in addition to the Internal IC temperature.
TM - Read Time
Alias: TIME HexCode: 1C CANOpen id: 0x2119
Description:
Reports the value of the time counter in controller models equipped with Real-Time
clocks with internal or external battery backup. On older controller models, time is count-