DS402 Runtime Queries
Advanced Digital Motor Controller User Manual 271
FEW - Following Error Window (DS402)
Alias: FEW HexCode:99 CanOpen id: 0x6065
Description:
Read the configured following error window for the position mode in counts. If the value
is FFFF FFFFh, the following control is disabled.
Syntax Serial: ?FEW [cc]
Reply: FEW=nn
Syntax Scripting: nn=SetCommand(_FEW, cc)
Argument: Channel Type: Unsigned 8-bit
Min: 1 Max: Total number of motors
Result: Value Type Unsigned 32-bit
Where:
cc= Motor Channel
nn = Following error window in counts
FET - Following Error Time Out (DS402)
Alias: FET HexCode:9A CanOpen id: 0x6066
Description:
Read the configured following error time out for the position mode in milliseconds.
Syntax Serial: ?FET[cc]
Reply: FET=nn
Syntax Scripting: nn = SetCommand(_FET, cc)
Argument: Channel Type: Unsigned 8-bit
Min: 1 Max: Total number of motors
Result: Value Type: Unsigned 16-bit
Where:
cc = Motor channel
nn= Following error time out