272 Advanced Digital Motor Controller User Manual V2.1, December 3, 2020
INT - Interpolation Time Period (DS402)
Alias: INT HexCode: 9C CanOpen id: 0x60C2
Description:
Read the parameters for the Interpolation cycle time. The interpolation time base is the
element 1 and the interpolation time index is element 2. The interpolation time value
comes out of the following formula:
<Interpolation Time(seconds)> = <Interpolation Time Base> x 10^<Interpolation Time
Index>
Syntax Serial: ?INT [ee]
Reply: INT=ee
Syntax Scripting: nn=GetValue(_INT,ee)
Argument: Element Type:Unsigned 8-bit
Min: 1 Max: 2xTotal number of motors
Result: Value Type: element 1: Unsigned 8-bit
element 2: Signed 8-bit
Where
ee=
1: Interpolation time base for channel 1
2: Interpolation time index for channel 1
3: Interpolation time base for channel 2
4: Interpolation time index for channel 2
...
2x(m-1)+1: Interpolation time base for channel m
2x(m-1)+2: Interpolation time index for channel m
MSL - Max Motor Speed (DS402)
Alias: MSL HexCode: 9B CanOpen id: 0x6080
Description:
Read the configured maximum motor speed in profile position, profile velocity, profile
torque, cyclic synchronous velocity, cyclic synchronous torque and cyclic synchronous po-
sition modes.