User Manual

Table Of Contents
Commands Reference
2 74 Advanced Digital Motor Controller User Manual V2.1, December 3, 2020
Result: Value Type: Unsigned 32-bit
Where:
cc = Motor channel
nn = Profile deceleration in 10×RPM/second
PLT - Software Position Limit (DS402)
Alias: PLT HexCode: 9D CanOpen id: 0x607D
Description:
Read the position limits.
Syntax Serial: ?PLT [ee]
Reply: PLT=nn
Syntax Scripting: nn = GetValue(_PLT, cc)
Argument: element Type: Unsigned 8-bit
Min: 1 Max: 2xTotal number of motors
Result: Value Type: element 1: Unsigned 8-bit
element 2: Signed 8-bit
Where
ee=
1: Software position min limit for channel 1
2: Software position max limit for channel 1
3: Software position min limit for channel 2
4: Software position max limit for channel 2
...
2x(m-1)+1: Software position min limit for channel m
2x(m-1)+2: Software position max limit for channel m
PST - Position Actual Value
Alias: PST HexCode: 95 CanOpen id: 0x6064
Description:
Read the actual value of the position sensor.