User Manual

Table Of Contents
DS402 Runtime Queries
Advanced Digital Motor Controller User Manual 275
Syntax Serial: ?PST[cc]
Reply: PST=nn
Syntax Scripting: nn = GetValue(_PST, cc)
Argument: Channel Type: Unsigned 8-bit
Min: 1 Max: Total number of motors
Result: Value Type: Singed 32-bit
POS – Target Position (DS402)
Alias: POS HexCode: 5C CANOpen id: 0x607A
Description:
Read the configured target position.
Syntax Serial: ?POS [cc]
Reply: POS=nn
Syntax Scripting: nn = GetValue(_POS, cc)
Argument: Channel Type: Unsigned 8-bit
Min: 1 Max: Total number of motors
Result: Value Type: Signed 32-bit
Where:
cc = Motor channel
nn = Target position
PSP – Profile Velocity (DS402)
Alias: PSP HexCode: 5D CANOpen id: 0x6081
Description:
Read the configured velocity in RPM.
Syntax Serial: ?PSP [cc]
Reply: PSP=nn
Syntax Scripting: nn = GetValue(_PSP, cc)
Argument: Channel Type: Unsigned 8-bit
Min: 1 Max: Total number of motors
Result: Value Type: Unsigned 16-bit