User Manual

Table Of Contents
DS402 Runtime Queries
Advanced Digital Motor Controller User Manual 279
Syntax Serial: !SDM
Reply: SDM=nn
Syntax Scripting: nn = GetValue(_TSL)
Result: Value Type: Unsigned 32-bit
Where:
nn = Supported drive modes
SPL – Velocity Min/Max Amount (DS402)
Alias: SPL HexCode: 57 CANOpen id: 0x6046
Description:
Read the configured minimum and maximum amount of velocity in RPM.
Syntax Serial: ?SPL [ee]
Reply: SPL=nn
Syntax Scripting: nn = GetValue(_SPL, ee)
Argument: Eelment Type: Unsigned 8-bit
Min: 1 Max: 2 × Total number of motors
Result: Value Type: Unsigned 32-bit
Where:
ee =
1: Min amount for channel 1
2: Max amount for channel 1
3: Min amount for channel 2
4: Max amount for channel 2
2 × (m - 1) + 1: Min amount for channel m.
2 × (m - 1) + 2: Max amount for channel m.
nn = Velocity max/min amount
SW – Status Word (DS402)
Alias: SW HexCode: 61 CANOpen id: 0x6041
Description: