User Manual

Table Of Contents
DS402 Runtime Queries
Advanced Digital Motor Controller User Manual 283
Profile Velocity Mode
TABLE 15-25. Status Word Mapping in Profile Velocity Mode
15 14 13 12 11 10 9 0
see Table 15-14
Not
Used
Speed
see
Table 15-14
Target
Reached
see Table 15-14
MSB LSB
In Profile Velocity Mode the operation specific bits are mapped in Table 15-25. With bits
10 and 12 user can acknowledge the status of the controller as shown in Table 15-26 and
Table 15-27. Bit 13 is always 0.
TABLE 15-26. Definition of bit 12 in Profile Velocity Mode
Bit Value Definition
12
0 Speed is not equal 0
1 Speed is equal 0
TABLE 15-27. Definition of Bit 12 in Profile Position Mode
Bit Value Definition
12
0 Previous set-point already processed, waiting for new set-point
1 Previous set-point still in process, set-point overwriting shall be accepted
Syntax Serial: ?SW [cc]
Reply: SW=nn
Syntax Scripting: nn = GetValue(_SW, cc)
Argument: Channel Type: Unsigned 8-bit
Min: 1 Max: Total number of motors
Result: Value Type: Unsigned 16-bit
Where:
cc = Motor channel
nn = Status word value
TC – Target Torque (DS402)
Alias: TC HexCode: 5B CANOpen id: 0x6071
Description:
Read the configured target torque in 100×Nm when the controller in torque mode.