User Manual

Table Of Contents
Commands Reference
296 Advanced Digital Motor Controller User Manual V2.1, December 3, 2020
TABLE 15-30. General and Safety Configurations
Command Arguments Description
ACS Enable Analog Center Command to Start
AMS Enable Analog keep within Guard Bands
BEE Address Value User Storage in Battery Backed RAM
BRUN Enable Script Auto-Start
CLIN Channel Linearity Command Linearity
CPRI Level Command Command Priorities
DFC Channel Value Default Command value
DMOD Mode Modbus Mode
ECHOF OffOn Enable/Disable Serial Echo
EE Address Data User-Defined Values
ISM None Raw Redirect Mode
MDAL Option Modbus Data Alignment
MNOD ID Modbus Slave ID
PMS Enable Pulse keep within Min & Max Safety
RS485 Enable Enable RS485
RSBR BitRate Set RS232/RS485 baudrate
RWD Timeout Serial Data Watchdog
SCRO Port Select Print output port for scripting
SKCTR Channel Center Spektrum Center
SKDB Channel Deadband Spektrum Deadband
SKLIN Channel Linearity Spektrum Linearity
SKMAX Channel Max Spektrum Max
SKMIN Channel Min Spektrum Min
SKUSE Channel Port Assign Spektrum port to motor command
STO Enable Safe Torque Off
TELS String Telemetry string
ACS - Analog Center Command to Start
HexCode: 0B
Description:
This parameter enables the analog safety that requires that the input be at zero
or centered before it can be considered as good. This safety is useful when oper-
ating with a joystick and requires that the joystick be centered at power up before mo-
tors can be made to run. On mutli-channel controllers, this configuration acts on all analog
command inputs, meaning that all joysticks must be centered before any one becomes
active.
Syntax Serial: ^ACS nn
~ACS
Syntax Scripting: setconfig(_ACS, nn)